CN/EN
CN/EN
Product show Nitrogen purification

Hydrogenation purification(H2 Deoxo)


The hydrogenation purification equipment adopts the catalytic deoxygenation + adsorption drying method. Under the catalyst, the trace oxygen in the general nitrogen reacts with hydrogen to remove the oxygen and produce water. The chemical reaction formula is 2H2+O2→2H2O+Q. Then through the adsorption drying device to remove impurities such as water, carbon dioxide, dust, etc., to obtain high-purity nitrogen. Because there is a small amount of hydrogen in the product gas, this equipment is suitable for users who have no special requirements for the hydrogen content of the product gas.

This equipment consists of nitrogen analyzer, flow meter, mass flow controller, programmable controller, deaerator, drying tower, refrigeration dryer, heat exchanger, filter, pipeline pneumatic valve, solenoid valve and control system.

Hydrogenation purification process flow chart


Features of hydrogenation purification equipment

1. Using the world's leading high-efficiency deoxidation catalyst, it has good activity, no heating, activation, and regeneration are required, and it has a good resistance to neutralization.

Toxicity, life span is more than 5 years;

2. Fully automatic control, automatic switching between work and regeneration, optional mass flow controller, automatic hydrogenation;

3. Adopt German Bold brand pneumatic valve, stable performance, safe and reliable;

4. The design is scientific, the structure is compact, the appearance is beautiful, and the floor space is small;

5. Use a heat exchanger to reduce the temperature of the mixed gas after deaeration, so that the equipment does not require cooling water;

6. Usually the product gas dew point D.P≤-60℃, which can meet the requirements of special users: product gas dew point D.P≤-70℃;

7. Low emission of renewable gas, saving energy.


Selection Guide

Product model (Ⅰ)
Gas production (Nm3/h)
Processing gas volume (Nm3/h)
Hydrogen consumption (Nm3/h)
Product nitrogen dew point (℃)
DC5N-20
20
twenty two
0.8
≤-65 (℃)
DC5N-30
30
33
1.2
DC5N-40
40
44
1.6
DC5N-50
50
55
2.0
DC5N-60
60
66
2.4
DC5N-80
80
88
3.2
DC5N-100
100
110
4.0
DC5N-150
150
165
6.0
DC5N-200
200
220
8.0
DC5N-300
300
330
12.0
DC5N-400
400
440
16.0
DC5N-500
500
550
20.0
DC5N-600
600
660
24.0
DC5N-700
800
880
32.0
DC5N-1000
1000
1100
40.0


The use conditions of this table: the purity of general nitrogen>98%, the design working pressure is 0.1MPa~1.0MPa.

Please contact the CAPTGAS sales engineer for specific requirements, the above is for reference only!


在线咨询QQ
Tel
Sales call:0512-66538016
0512-66538017
Wechat
TOP

Click to add WeChat

Captgas equipment Co., Ltd-Suzhou